high voltage cable couplers, junction bars, trailing cable coupler, design and manufacturing, ship to shore power, cold ironing, trolley shoes, substation, cable bracket, bus support, capnut termination, cable transitions, ground fault protection, PILC Cable, aircraft warning marker, oil stop module, mining products, utility products, patton, cooke


mining products utility products transportation products tunnel boring machines & shore power Patton & Cooke Company
home
products
brochures
case studies
multimedia
contact us
utility > products > cable transition modules

 

Cable Transition Modules

Patton & Cooke Co.'s CTM's are designed for splicing PILC into solid dielectric cable. P&C modules allow easy and reliable construction of single phase taps or splices from PILC distribution cable feeders using Separable insulated Connectors (i.e. Rubber Elbows). CTM's are rated for 15, 35, or 35 kV applications and are available in 200, 600 or 900 Amp configurations.

Cast from P&C's exclusive thermal setting resin, our CTM's possess the same properties as our junction bars. P&C CTM's are a unique integration of a PILC splice and a junction bar& in one device.

Cable Transition Module Catalog Numbers 

Application: Paper Insulated Lead Covered Cable (PILC) Run to Solid Dielectric Tap

Illustration
(not to scale)

Description

P & C
Cat No

Dimensions

Weight

Length

Width

Height

mm

in

mm

in

mm

in

kg

lb

15 or 25 kV
Straight 
thru trans
3 Point
200 Amp
Dielectric
Tap

CTM-005A

216

8.50

406

9.67

216

8.50

8

18

15 or 25 kV
Straight thru
trans
3 Point
600 Amp
Dielectric
Tap

CTM-012A

235

9.25

318

12.50

235

9.25

9

20

15 or 25 kV
Tap trans
3 Point 
200 Amp
Dielectric
Tap

CTM-015A

356

14.00

260

10.25

254

10.00

15

33

15 or 25 kV
Tap trans
6 Point 
200 Amp
Dielectric
Tap

CTM-025A

356

14.00

375

4.75

251

9.88

28

62

15 or 25 kV
Tap trans
3 Point 
600 Amp
Dielectric
Tap

CTM-011A

356

14.00

260

10.25

356

14.00

16

36

15 or 25 kV
Tap trans
6 Point 
600 Amp
Dielectric
Tap

CTM-020A

356

14.00

375

14.75

356

14.00

31

68

15 or 25 kV
Run & Tap
trans
3 Point 
200 Amp
Dielectric
Tap,
3 Point 
600 Amp 
PILC Tap

CTM-010A

356

14.00

406

16.00

251

9.88

17

37

15 or 25 kV
Run & Tap
trans
6 Point 
200 Amp
Dielectric
Tap,
6 Point 
600 Amp 
PILC Tap

CTM-024A

356

14.00

521

20.50

251

9.88

30

66

15 or 25 kV
Run & Tap
 trans
3 Point 
600 Amp
Dielectric
Tap,
3 Point 
600 Amp 
PILC Tap

CTM-009A

356

14.00

406

16.00

356

14.00

18

40

15 or 25 kV
Run & Tap
 trans
6 Point 
600 Amp
Dielectric
Tap,
6 Point 
600 Amp 
PILC Tap

CTM-019A

356

14.00

521

20.50

356

14.00

33

72

35 kV
Tap trans
3 Point 
600 Amp
Dielectric
Tap

CTM-033A

400

15.75

438

17.25

413

16.25

38

84

35 kV
Tap trans
6 Point 
600 Amp
Dielectric
Tap

CTM-034A

400

15.75

578

22.75

413

16.25

69

152

Application: Paper Insulated Lead Cable (PILC) Run to Solid Dielectric Taps

Illustration
(not to scale)
Description P & C
Cat No
Dimensions Weight
Length Width Height
mm in mm in mm in kg lb

15 or 25 kV
Straight
thru
3 Point 
200 Amp
Dielectric
Tap,
3 Point 
600 Amp
PILC Tap
CTM-029A 356 14.00 362 14.25 254 10.00 18 40

15 or 25 kV
Straight thru
3 Point
600 Amp
Dielectric
Tap,
3 Point
600 Amp
PILC Tap
CTM-030A 356 14.00 362 14.25 356 14.00 21 46
 
ACCESSORIES:    
 
  • Mounting brackets
  • Wiping sleeves
  • Wiping Flanges
   
       
SELECTION REMINDERS:    
       
1.
Standard ratings for 15 or 25 kV
4.
 All cable transition modules are
modules: 

Impulse Voltage: 95 or 125k BIL Corona Extinction: 11 or 19 kV
for use with molded separable insulated connectors.
Standard ratings for 35
5.
Standard modules are for horizon-
kV modules:    tal mounting. For unique transition
Impulse Voltage: 150 kV BIL   splicing requirements contact
Corona Extinction: 26 kV
factory.
 
2.
All cable transition modules are
6.
For 900 Amp applications,
  standard equipped with solder   contact factory.
  lugs and protective covers.
 
7.
Weights and dimensions
3.
Wiping sleeves and mounting are approximate.
brackets are sold separately. 
   
ORDERING PROCEDURE:
1. Determine the following: 
4.
Specify if mounting brackets or 
a. Maximum voltage, kV.   wiping sleeves are required.
b.  Current Rating of tap(s), Amp    
c. Transition configuration Example:
    15kV, 600 Amp run with 3 point,
2. Select catalog number of cable 200 Amp tap, run & tap
transition module. transition configuration
   
3. Provide the conductor size and CTM Catalog Number   CTM-011A
  type of cable.
     